Fire-resistant cables

Our fire-resistant marine and offshore cable is designed for use in fixed installations for power circuits, emergency lighting systems, and fire alarm systems. It is robust, flexible and suitable for indoor and outside use and with the armour protection may be used in areas subject to impact.

  • Marine and offshore cable, fire-resistant EPR individually screened – UKOOA, BS 7917/6883

Tinned stranded circular copper conductor to BS 6360 Class 2 EPR, GP4 insulation to BS 7655: section 1.2 Mica glass tape insulation, EPR, GP4 insulation to BS 7655: section 1.2 colour coded cores twisted to form a pair, triple or quad-wrapped with polyester tape.

Collective screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant, halogen-free bedding, PET tape and rubberised polyamide tape inner covering, galvanised-steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound. (LSF) SW4 outer sheath to BS 7655 section 2.6. 150V/250V grade manufactured to BS 7917/6883 and UKOOA design flame retardant to IEC 60332-1 and IEC 60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21

  • Marine and offshore cable, fire-resistant MGT, BS 7917/6883

Available in 1.5mm to 16mm and manufactured to BS 7917/6883. The cable features tinned, annealed, stranded copper conductors, MICA glass-taped, ethylene propylene rubber (EPR) insulated low smoke, zero halogen (LSZH) bedding, galvanised-steel wire braid armour, low smoke, zero halogen (SW4) outer sheath to BS 7655-2,6.Black. 600/1000 volts grade to BS 7917/6883, IEC 60332-1, IEC 60332-3-22, IEC 61034-1,2, IEC 60754-1,2 and IEC 60331-21

  • Marine and offshore cable, fire-resistant EPR overall sScreened – UKOOA, BS 7917/6883

Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655:section 1.2 Mica glass tape insulation, EPR, GP4 insulation to BS 7655: section 1.2 colour coded cores twisted to form a pair, triple or quad-wrapped with polyester tape.

Collective screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised-steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil-resisting thermosetting compound. (LSF) SW4 outer sheath to BS 7655 section 2.6.150V/250V grade manufactured to BS7917/BS6883 and UKOOA design flame retardant to IEC 60332-1 and IEC 60332-3-22. Halogen free to IEC 60754-1,2 and low smoke to IEC 61034-1,2. Fire resistant to IEC 60331-21.